testkit - photometers |
| The Cullwater offers a large range of test kits and analytical instruments for a complete analysis of several chemical parameters for drinkable water, process water and swimming pools. Their easy use permits the employment for final customers and water treatments/swimming pools companies. |
| |
Test Kit for the control of single chemical water parameters
with two modality of analysis: with colorimetric scale or with titolation. |
Acidity M tit.
Alkalinity M - P tit.
Alkalinity of the boiler tit.
Carbon dioxide tit.
Ammonia col. 0,25-4 ppm
Calcium tit.
Total Chlorine col. 0,1-1,5 ppm
Chlorides tit.
Chlorides col. 0-80 ppm
Hardness ECO monocomponent tit.
Hardness bicomponent tit.
Hardness precipitation
Iron col. 0,05-15 ppm
Phosphate col. 1-20 ppm
Phosphate col. 5-100 ppm
|
Manganese col. 0,05-1,5 ppm
Nitrites col. 0,05-1,5 ppm
Nitrates col. 10-140 ppm
pH 6,8-8,4 col.
pH 1-11 universal col.
pH - Chlorine with reagents in tablets
pH - Chlorine with liquid reagents
pH - Chlorine/Bromime - Alkalinity (50 strips)
pH - Bromime with reagents in tablets
pH - Active Oxigen with reagents in tablets
Cyanuric acid with reagents in tablets
Tablets DPD - Phenol Red 10 analysis
Silica col. 0,25-8 ppm
Solphites tit. 2 ppm
Solphites tit. 10 ppm |
| |
|
| |
pH Tester
Calibration in 1 point
Scale: 0.0 - 14.0 pH
Precision: ± 0.2 pH |
|
pH waterproof Tester
Manual calibration in 2 points
Scale: 0.0 - 14.0 pH
Precision: ± 0.1 pH
Replaceable pH electrode |
 |
 |
| |
pH / °C waterproof Tester
Display at 1 level
Automatic calibration in 2 points
Scale: –2.0 - 16.0 pH / 0.0 -60.0 °C
Precision: ± 0.1 pH / ±1° C
Automatic compensation of the temperature
Replaceable pH electrode |
|
pH / °C waterproof Tester
Display at 2 levels
Automatic calibration in 2 points
Scale: –2.0 - 16.0 pH / 0.0-60.0 °C
Precision: ± 0.1 pH / ±1° C
Automatic compensation of the temperature
Replaceable pH electrode |
 |
 |
| |
pH / Redox / °C
waterproof Tester
Display at 2 levels
Automatic Calibration in 2 points
Scale: 2.00 - 16.00 pH / ± 1000mV Redox / -5.0 - 60.0 °C
Precision ± 0.01 pH; 1mV
Replaceable combined electrode |
|
Salinity (TDS) waterproof Tester
Manual calibration in 1 point
Scale: 0 - 9990 ppm (mg/l) µs/cm
Precision: ± 2 % in whole scale
Automatic compensation of the temperature
Replaceable electrode |
 |
 |
| |
Conductivity waterproof Tester
Manual calibration in 1 points
Scale: 0 - 1999 µs/cm
Precision: ± 2 % in whole scale
Automatic compensation of the temperature
Replaceable pH electrode |
|
Salinity / Conductivity / °C waterproof Tester
Display at 2 levels
Automatic calibration in 2 points
Scale: 3999 µs/cm / 2000 ppm. 0 at 60.0 °C
Precision: 1 µs/cm / 1 ppm
Replaceable combined electrode |
 |
 |
| |
| Portable instruments suitable to every necessity of utilization |
| |
pH / Conductivity / TDS
multi-parameter instrument
Scale: 0.0 - 14.0 pH / 0 - 9990 ppm / 0 - 1990 µs/cm
Precision: ± 0.2 pH and ± 2% at whole scale (Conductivity and TDS) )
Supplied with combined electrode, 9 V battery, bag of buffer solution (pH 7.01, 1382 ppm e 1.413 µs/cm). |
|
pH / °C instrument
Scale: -2.00 - 16.00 pH / -5.0 - 70°C
Precision: ± 0.01 pH
Automatic compensation of the temperature and automatic calibration in 1 or 2 points.
Supplied with pH electrode with double washer and temperature probe, a 9 V battery and 20 ml bag of buffer solution pH 7.01. |
 |
 |
| |
Redox instrument
Scale: ± 1000 mV
Precision of ± 5 mV
Supplied with an electrode in platinum and a 9 V battery. |
|
pH instrument
Manual calibration in 1 or 2 points
Scale: 0.0 - 14.0
Precision ± 0.2 pH
Scale of set point: 5.5 - 9.5 pH
Visual alarm at active led when the reading is higher than the set-point.
Supplied with an adaptor 12 VDC, pH electrode, 20 ml of buffer solution 7.01 pH and a screwdriver for the calibration. |
 |
 |
| |
Conductivity instrument
Manual calibration in 1 point
Scale: 0 - 1990 ±s/cm
Automatic compensation of the temperature
Supplied with conductivity probe, 9 V battery, 20 ml bag of buffer solution 1.413 ±s/cm and a screwdriver for the calibration. |
|
Dissolved Oxygen (D.O.) instrument
Scale: 0.0 - 19.9 g/l O2
R
esolution 0.1 ppm
Precision in whole scale ± 1.5%
Supplied with a polar graphic probe for dissolved oxygen with a 3 meters cable, electrolyte solution of oxygen, (bottle of 20 ml),
screwdriver for calibration, 9 V battery and user manual. |
 |
 |
| |
pH / °C instrument
Automatic calibration in 1 or 2 points
Scale: -2.00 - 16.00 pH; -5.0 - 80°C
Resolution 0.01 pH
Precision ± 0.02 pH
Automatic compensation of the temperature
Supplied with an amplified probe pH/Temperature, 9 V battery, solutions of setting pH 4.01 (20 ml), pH 7.01 (20 ml), pH 10.01 (20 ml), cleaning solution (20ml) and user manual. |
|
pH / Redox / °C instrument
Automatic calibration in 1 or 2 points
Scale: -2.00 - 16 pH, -2000 - + 2000 mV, -5.0 - 80.0 °C
Resolution 0.01 pH / 1 mV / 0.1 °C
Precision (25 °C) ± 0.02 pH / ±2 mV, ±0.5 °C till to 60 °C, ± 1 °C and automatic compensation of the temperature
Supplied with an amplified probe pH/Redox/Temperature 9 V battery, setting solution pH
(20 ml) pH 7.01 (20 ml) pH.10.01 (20 ml), cleaning solution (20 ml) and user manual. |
 |
 |
| |
pH / Conductivity / TDS / °C multi-parameter instrument
pH Calibration in 1 or 2 points with automatic recognition of the samples, calibration automatic conductibility in 1 point
Scale: 0.00 -14.00 pH, 0 - 3999 µs/cm, 0 - 1999 ppm, 0.0 - 60.0 °C
Resolution 0.01 pH / 1µs/cm / 1 ppm / 0.1 °C
Precision (at 25 °C) ±0.01 pH / ±2% fs / ±0.5 °C
automatic compensation of the temperature
Supplied with an amplified probe, 9 V battery, some solutions of setting pH 4.01 (20 ml) pH 7.01 (20 ml), cleaning solution (20 ml), solution of setting conductibility 1413 µS/cm (20 ml) and user manual. |
|
Conductivity / TDS / NaCl / °C instrument
Automatic calibration
Scale: 0.0 - 2999 µs/ cm, 3.00 - 500.0 ms/cm; 0.00 - 1499 mg/l, 1.50 - 400.0 g/l; NaCl 0.0 - 400.0 %; -9.9 - 120.0 °C Automatic compensation of the temperature, possibility to register more than 250 values in the memory
Auto ranging function, function of (hold) auto end point
Supplied with a PC software, probe, 9 V battery, solution of setting conductibility 12880 µS/cm (bottle 230 ml) and user manual. |
 |
 |
| |
Dissolved Oxygen instrument (D.O.)
Automatic air calibration
Scale 0.0 - 45.00 mg/l O2; 0.0 - 300 % O2; 0.0 - 50.0 °C
Resolution 0.01 mg/l O2; 0.1 % O2; 0.1 °C
Precision: (at 25°C) ± 0.3 mg/l O2; ± 1.5% f.s. %O2, ± 0.5°C
Automatic compensation of the temperature, of the altitude from 0 at 4 km and from the salinity from 0 to 80 g/l, resolution 1 g/l
Supplied with a probe, 9 V battery, an electrolyte solution (bottle of 20 ml), 2 membranes and user manual. |
 |
| Multi-parameter photometers with use of reagents already prepared for analysis |
| |
Free Chlorine / Total chlorine / pH / Cyanuric acid
Electronic Tester
Scale: 0.00 - 6.00 mg/l of Cl2; 0.00 - 13.0 mg/l; 6.5 - 8.4 pH; 0 - 80,0 mg/l
Cyanuric acid
Battery 9 Volt (included)
Automatic switch off
LCD screen
Conditions of working: Temperature: 0 - 40 °C – Relative humidity: 30-90%
|
 |
| |
Free Chlorine / Total Chlorine / Bromime / pH / Cyanuric acid / Alkalinity Electronic Tester
Scale: 0.00 - 6.00 mg/l of Cl2; 0.00 - 13.0 mg/l; 6.5 - 8.4 pH; 0 -80,0 mg/l Cyanuric acid; 0.00 - 500 mg/l CaCO3
Battery 9 Volt (included)
Automatic switch off
LCD screen
Conditions of working: Temperature: 0 - 40 °C – relative humidity: 30-90%
|
 |
| |
Free and Total Chlorine instrument
Scale: 0.00 - 5.00 mg/l of Cl2 (free and total)
Precisions: ± 0.04 mg/l at 1.50 mg/l
Supplied in rigid suitcase with reagents, 2 cuvettes, cleaning cloth and user manual.
|
 |
| |
pH and Total/ Free Chlorine instrument
Scale: 0.00 - 5.00 mg/l of Cl2 (free and total)
Precision: ± 0.04 mg/l at 1.50 mg/l
Supplied in rigid suitcase with reagents, 2 cuvettes, cleaning cloth and user manual.
|
 |
| |
pH – Free and Total Chlorine – Cyanuric acid instrument
Scale: Chlorine 0, 05 - 4, 00 ppm; pH 6, 5 - 8, 4; Cyanuric acid 2 - 160 ppm
Reading of the values through wide digital display with 3 numerals.
Supplied in rigid suitcase with reagents, battery and accessories for the cleaning. User manual.
|
 |
| |
pH – Total and Free Chlorine – Cyanuric acid - Hardness - Alkalinity instrument
Scale: Chlorine 0,05 - 4,00 ppm; pH 6,5 - 8,4; Cyanuric acid 2 - 160 ppm; Hardness 50 - 500 mg/l; Alkalinity 5 - 200 mg/l
Reading of the values through wide digital display with 3 numerals.
Supplied with suitcase, reagents, battery and accessories for the cleaning. User manual.
|
 |
| |
Turbidimeter
Calibration on three points 0, 10 and 500 FTU
Scale: FTU 0.00 - 50.00 and 50 - 1000 FTU
Resolution 0.01 (0.00 - 50.00 FTU) and 1 (50 - 1000 FTU)
Light source with infrared Led, a sensor at photocell in silicon, a power supply through battery, with switch off after 5 minutes from the last utilization.
Supplied in rigid suitcase with solutions of calibrations, measuring cuvettes, cleaning cloth and user manual.
|
 |
| |
Ammonia MR – Nessler method instrument
Scale: 0.00 - 9.99 mg/l (NH3-N)
Precision: ± 0.10 mg/l at 5.00 mg/l
Supplied in rigid suitcase with two cuvetts, reagents, cleaning cloth and user manual.
|
 |
| |
Ammonia LR – Nessler method instrument
Scale: 0.00 - 3.00 mg/l (NH3-N)
Precision: ± 0.04 mg/l at 1.50 mg/l
Supplied in rigid suitcase with two cuvetts, reagents, cleaning cloth and user manual.
|
 |
| |
Iron HR instrument
Scale: 0.00 - 5.00 mg/l of Fe
Precision: ± 0.03 mg/l - 1.50 mg/l
Supplied in rigid suitcase with two cuvetts, reagents, cleaning cloth and user manual.
|
 |
| |
Phosphate LR instrument
Scale: 0.00 - 2.50 mg/l of PO4
Precision: ± 0.04 mg/l at 1.00 mg/l
Supplied in rigid suitcase with two cuvetts, reagents, cleaning cloth and user manual.
|
 |
| |
Chlorides instrument
Scale: 0.00 - 20.00 mg/l of Cl
Precision: ± 0.4 mg/l at 10.0 mg/l
Supplied in rigid suitcase with two cuvetts, reagents, cleaning cloth and user manual.
|
 |
| |
|
|